 | Product Details: 
 Payment & Shipping Terms: 
 | 
| Ranging Method: | 1ToF | Detection Distance: | 200m@90% Reflectivity/ 140m@10% Reflectivity | 
|---|---|---|---|
| Range Resolution: | ≤0.1m | Measurement Accuracy: | ±0.2m | 
| Repeated Measurement Accuracy: | ±0.2m | Resistance To Ambient Light: | 100Klux | 
| Wavelength: | 905nm | Repeat Frequency: | 20KHz Per Channel | 
| Laser Safety Level: | Class 1 | Range Of Working Temperature: | -40℃~+60℃ | 
| Survival Temperature Range: | -45℃~+65℃ | Working Humidity Range: | 0%~100% RH | 
| Enclosure Rating: | IP65 (or According To Specific Needs) | Working Acceleration Range: | -0.5g ~ 0.5g | 
| Luminous Flux 1: | 0° | Luminous Flux 2: | 2.05°±0.2° | 
| Luminous Flux 3: | 4.09°±0.2° | Real-time Data Products: | Device ID, Directly Measure Distance, Return Light Intensity, Data Valid Flag, System Status | 
| Fieldbus: | Profibus DP / Modbus RTU / CANopen Three Fieldbus Protocols, And RS485 Communication Can Be Customized | Operating Power Consumption: | Within 60W | 
| Supply Voltage And Maximum Current: | DC 24V, 3A | Size: | 200×200×250mm | 
| Highlight: | Molas CL Wind Lidar 200mm,Molas CL Wind Lidar 250mm,DC 24V 3A Wind Measurement Lidar | ||
Offshore Wind Lidar Molas CL IP65 Silver Prevent tower sweeping
1,Product introduction
MolasCL laser clearance monitoring radar is a kind of lidar that monitors the blade tip clearance distance in real time.
2,Technical Data Sheet
| Ranging index | |
| Ranging method | 1ToF | 
| Detection distance | 200m@90% reflectivity/ 140m@10% reflectivity | 
| Range resolution | ≤0.1m | 
| Measurement accuracy | ±0.2m | 
| Repeated measurement accuracy | ±0.2m | 
| Resistance to ambient light | 100Klux | 
| Optical index | |
| Wavelength | 905nm | 
| Repeat frequency | 20KHz per channel | 
| Laser safety level | Class 1 | 
| Environmental adaptability | |
| Range of working temperature | -40℃~+60℃ | 
| Survival temperature range | -45℃~+65℃ | 
| Working humidity range | 0%~100% RH | 
| Enclosure rating | IP65 (or according to specific needs) | 
| Working acceleration range | -0.5g ~ 0.5g | 
| Beam pointing | |
| Luminous flux 1 | 0° | 
| Luminous flux 2 | 2.05°±0.2° | 
| Luminous flux 3 | 4.09°±0.2° | 
| Output measurement results | |
| Real-time data products | Device ID, directly measure distance, return light intensity, Data valid flag, system status | 
| Fieldbus | Profibus DP / Modbus RTU / CANopen Three fieldbus protocols, and RS485 communication can be customized | 
| Qther | |
| Operating power consumption | Within 60W | 
| Supply voltage and maximum current | DC 24V, 3A | 
| Size | 200×200×250mm | 

Contact Person: ivyyao
Tel: +86 13072523225
Fax: 86-025-86800073