Product Details:
Payment & Shipping Terms:
|
Ranging Method: | 1ToF | Detection Distance: | 200m@90% Reflectivity/ 140m@10% Reflectivity |
---|---|---|---|
Range Resolution: | ≤0.1m | Measurement Accuracy: | ±0.2m |
Repeated Measurement Accuracy: | ±0.2m | Resistance To Ambient Light: | 100Klux |
Wavelength: | 905nm | Repeat Frequency: | 20KHz Per Channel |
Laser Safety Level: | Class 1 | Range Of Working Temperature: | -40℃~+60℃ |
Survival Temperature Range: | -45℃~+65℃ | Working Humidity Range: | 0%~100% RH |
Enclosure Rating: | IP65 (or According To Specific Needs) | Working Acceleration Range: | -0.5g ~ 0.5g |
Luminous Flux 1: | 0° | Luminous Flux 2: | 2.05°±0.2° |
Operating Power Consumption: | Within 60W | Supply Voltage And Maximum Current: | DC 24V, 3A |
Size: | 200×200×250mm | ||
High Light: | Laser Safe MOVELASER Wind Lidar,MOVELASER Wind Lidar For Wind Turbines,60W lidar for wind turbines |
MOVELASER Wind Lidar Laser safety level Class 1
1,Product introduction
The wind turbine tower clearance is the closest distance between the blade tip of the unit blade and the tower wall at the height of the blade tip. With the development of fan technology and the improvement of energy efficiency requirements, fan blades are getting longer and softer. At the same time, due to the complex geographical environment of the fan site, complex wind conditions or complex meteorological conditions such as cold current and typhoon, the fan The blade has the risk of sweeping the tower. After sweeping the tower, the blade will be replaced in light, and the entire unit will be scrapped in severe case, which will bring huge economic and property losses.
2,Technical Data Sheet
Ranging index | |
Ranging method | 1ToF |
Detection distance | 200m@90% reflectivity/ 140m@10% reflectivity |
Range resolution | ≤0.1m |
Measurement accuracy | ±0.2m |
Repeated measurement accuracy | ±0.2m |
Resistance to ambient light | 100Klux |
Optical index | |
Wavelength | 905nm |
Repeat frequency | 20KHz per channel |
Laser safety level | Class 1 |
Environmental adaptability | |
Range of working temperature | -40℃~+60℃ |
Survival temperature range | -45℃~+65℃ |
Working humidity range | 0%~100% RH |
Enclosure rating | IP65 (or according to specific needs) |
Working acceleration range | -0.5g ~ 0.5g |
Beam pointing | |
Luminous flux 1 | 0° |
Luminous flux 2 | 2.05°±0.2° |
Luminous flux 3 | 4.09°±0.2° |
Output measurement results | |
Real-time data products |
Device ID, directly measure distance, return light intensity, Data valid flag, system status |
Fieldbus | Profibus DP / Modbus RTU / CANopen Three fieldbus protocols, and RS485 communication can be customized |
Qther | |
Operating power consumption | Within 60W |
Supply voltage and maximum current | DC 24V, 3A |
Size | 200×200×250mm |
Contact Person: ivyyao
Tel: +86 13072523225
Fax: 86-025-86800073